INFINITT Cardiology PACS

INFINITT Cardiology PACS

  • Intended Use

INFINITT Cardiology PACS is a web-based DICOM viewing station running on Windows. It is adapted for, storing, processing routing and report generating.

INFINITT Cardiology PACS fully supports the DICOM standard and such functions as advanced DICOM viewing, Hanging Protocol, Echocardiography, Cardiovascular, EKG and Angiography.

INFINITT Cardiology PACS allows users to take full advantage of the radiographic and Echo images from various modalities in order to obtain invaluable mission critical diagnostic data and images. With INFINITT Cardiology PACS, users can have the same diagnostic environment of their own anywhere anytime because INFINITT Cardiology PACS is deployed through network and supports hanging protocol radically.

INFINITT Cardiology PACS is a software device that does not contact the patient, nor does it control any life sustaining devices.

The software does not provide any diagnostic assistance to the physician. Any diagnostic determination or treatment is solely determined by a physician and not the software.

A physician, providing ample opportunity for competent human intervention, interprets images and information being displayed and printed. 

INFINITT Cardiology PACS is in conformity with the essential requirements and provisions of Council Directive 93/42/EEC

INFINITT Cardiology PACS is in conformity with the harmonized standards

EN ISO 13485:2003, EN 14971:2007, EN 60601-1-4:1996,

EN 980:2008 and EN 1041:2008

ISO 14155-1:2003, EN 62304: 2006

 

  • Precaution

1. Only Experts should use this medical imaging solution.

2. Take notice of the following before installing this medical imaging solution.

  • Confirm available disk capacity.

  • Confirm that all related devices Image receiver, image inquirer and image transmitter are turned on.

  • Always use the assigned ID and password to login.

 

3. Take notice of the following while using this medical imaging solution.

  • Do not save or delete patient images without proper authorization.

  • Do not use functions that you are not familiar with.

  • Do not shut down the system or close down the program unnecessarily.

 

4. Take notice of the following after using this medical imaging solution.

  • Close all opened exams after use. 

  • Always log off after using the program.

  • Never turn off the power of the picture archiving system.

  • Always make sure the system is dry and at the appropriate temperature.

5. If the program arrives unexpectedly, please refer to appendix X's Trouble shooting.

 

  • INFINITT Cardiology PACS



  •  

INFINITT Cardiology PACS is a web-based DICOM viewing station that runs on Windows 7, 8, 10. It is adapted for storage, processing, routing and report generation. INFINITT Cardiology PACS fully supports the DICOM standard and such functions as advanced DICOM viewing, Hanging Protocol, Echocardiography, Cardiovascular, EKG and Angiography. INFINITT Cardiology PACS allows users to take full advantage of radiographic and Echo images from various modalities in order to obtain invaluable mission critical diagnostic information and images. With INFINITT Cardiology PACS, users can have their own customized diagnostic environment anywhere anytime. INFINITT Cardiology PACS is deployed through the web and supports hanging protocol globally. Also INFINITT Cardiology PACS utilizes JPEG 2000 compression features so that it takes less time to transfer images through the network. INFINITT Cardiology PACS supports interoperability between IHE approved workstations (Integrating the Healthcare Enterprise) with security functions.


 

  • INFINITT Healthcare

INFINITT Healthcare is a company which specialized in the development of PACS and Tele-radiology. We seek to provide image management solutions for medical institutions and healthcare professionals throughout the world with state-of-the-art technology acquired through over 20 years of dedication to digital image management systems. INFINITT’s business philosophy is TO PROVIDE THE CUSTOMER WITH THE BEST QUALITY AND RELIABLE SERVICE, which naturally leads to complete customer satisfaction.

    • If you type it manually (Manual Entry), the color dose not change.

    reason : too many manual inputs

    • ‘Value log’ are saved every time when you save the report (even if values has not changed)

    • Value log offers log to the every field including the Measurement

  • Measurement flags and Value logs 

    • Summary

    • About

    • Measurement source can be distinguished by Colors.

    • Viewing the history of value or modifying the value (include measurement values)

    • Related Issue

     Measurement Flags and logs

    • Configuration Method

    •  Action_code

    • Cardiology Report – Report Log setting (Action_code = 2014)

    Operations

    • ‘Measurement Flags’ Display Setting

    • Measurement Flags function settings can be supported by individual user’s User Setting 

    • Setting 🡪 Report 🡪 General 🡪 click Measurement Flags 

    • If the corresponding setting is True, Measurement Flags function is activated in the report